Whole range of 22 Generators Energy Gruppi models, offered for sale from € 829.23 , in Prompt Delivery and Free shipping . Purchase directly from AgriEuro with no third parties nor unwanted surpreses: compared to the other online markets, who rely on third dealers (it means no assistance nor warranty), we offer Direct and Complete Assistance, which starts from pre-sales service up to after-sales assistance. The items are directly shipped from our AgriEuro distribution centre. Thus, we are the only online seller providing After-Sales Assistance for the Generators Energy Gruppi products and supplying Spare Parts (you access the exploded drawing once entered your Account).
Energy Gruppi is an Italian company officially founded in 2003 in Montebello Vicentino, specialising in the design and production of generating sets. Established on the foundations of previous family business experience, between 2007 and 2009 it consolidated its international presence by supplying over 2,000 generators to the Middle East. Its growth continued with its transformation into a limited company in 2011, the expansion of its production facilities and the in-house integration of metalwork and electrical-panel manufacturing.
Energy Gruppi power generators are designed for civil, agricultural, craft and industrial applications, as well as emergency power supply. Italian production, mechanical and electrical testing and the availability of single-phase and three-phase configurations make it possible to identify suitable solutions for tools, machinery and appliances with different power requirements. The documented range includes outputs from 3 kW to 11.8 kW and configurations with Honda GX or Briggs & Stratton Vanguard engines and LINZ Electric alternators, depending on the model.
This page also includes the following types of Energy generating sets, divided according to fuel type and starting system:
At AgriEuro, Energy Gruppi power generators can be selected according to their technical features, helping users choose a model suited to the appliances to be powered and the expected frequency of operation.
Professional configurations can power compatible construction equipment, workshop machinery and agricultural appliances. Models intended for emergency applications can be used at homes, businesses and facilities requiring an alternative power source, subject to correct sizing and the specified installation procedures.
The available types meet different requirements in terms of operating frequency, power and activation method. The fuel type affects the operating context; the starting system determines how the generating set enters service. The comparison should therefore begin with the connected appliances, their required starting current and the expected operating time.
Energy Gruppi petrol generators are suitable for temporary work, mobile operations and backup power in domestic, craft or agricultural settings. They can supply compatible tools and appliances in locations without access to the mains or during occasional power cuts. The choice requires a comparison between rated power, maximum power and starting demand, as power tools, pumps and compressors may require more energy during start-up. Documented configurations include Honda GX-series and Briggs & Stratton Vanguard engines, combined with specific alternators and socket panels depending on the model. Single-phase versions are designed for 230 V appliances; three-phase versions serve compatible 400 V machinery. Before purchasing, check the running time, starting method, electrical protections, weight and equipment supplied with the individual machine.
Aspects to compare include:
Energy Gruppi diesel generators are aimed at professional applications requiring frequent duty cycles and a structure suited to the expected operating environment. They can serve construction sites, farms, workshops and production facilities, provided that their output and electrical configuration are consistent with the connected loads. The selection includes single-phase and three-phase models, with power ratings intended for different tools, pumps, machinery and backup appliances. In addition to rated output, users should assess the required starting peak, the number of sockets, protections, fuel-tank capacity and starting method. Weight and any transport features affect the positioning of the machine. For extended or emergency applications, maintenance intervals, ventilation, exhaust-gas discharge and the manufacturer's instructions must also be followed.
The main elements to assess are:
Energy Gruppi automatic-start generators are designed to enter service when the main power source is unavailable, as part of a correctly configured system. The transfer panel detects the mains failure, sends the starting command and transfers the power supply to the selected appliances. When mains power is restored, the system returns the load to the primary source and completes the cycle according to the installed control logic. This solution is suitable for homes, companies, workshops and facilities where a power cut could stop priority equipment or services. The power rating must be calculated according to the appliances that must remain active, including the starting demand of electric motors. Compatibility between the generator, ATS panel, voltage and wiring diagram must also be checked. Connections, protections and earthing require assessment by a qualified technician and compliance with the manufacturer's instructions.
For a correct selection, the following must be considered:
Purchasing an Energy Gruppi generator from AgriEuro combines technical product selection with dedicated services before and after delivery. Logistics availability, access to spare parts and specialist support accompany the product throughout its operating life.
Buy the Energy Gruppi power generator best suited to your requirements from AgriEuro now.
The power rating is chosen by adding together the demand of appliances operating at the same time and allowing a margin for starting peaks. Pumps, compressors, refrigerators and power tools may require more power at start-up than their rated consumption. The result should be compared with the generator's continuous output, not only its maximum rating. Voltage, frequency and current type must also match the information on the equipment rating plates.
The main difference concerns the fuel type and operating profile. Petrol generators are suitable for temporary work, mobile activities and occasional operation. Diesel models are also intended for frequent professional applications, subject to the specified duty cycle. The choice should consider the duration of the work, required power, starting frequency, running time, weight and maintenance specified for the individual model.
A single-phase generator normally supplies 230 V appliances; a three-phase model is intended for compatible 400 V machinery. The presence of a three-phase socket does not mean that the generator is suitable for every load. Check the voltage, demand and power distribution stated on the technical data sheet. If both types of appliance need to be connected, the power actually available from each output must be checked carefully.
Automatic starting requires a compatible generator and ATS panel. When the mains fails, the system detects the interruption, starts the engine and transfers the selected appliances to the generating set. Once mains power returns, the panel transfers the load back and stops the generator according to the configured sequence. Design, connection and commissioning must be performed by qualified personnel.
Yes, provided the model is sized for the priority loads and the electrical system has suitable connections and protections. Users should determine which appliances must remain active, such as lighting, a refrigerator, boiler or pumps, and calculate their demand and starting peaks. The generator must not be connected directly to the electrical system using improvised solutions. A transfer system that isolates the mains and an installation completed in accordance with applicable regulations are required.
Rated power indicates the output available under the operating conditions defined by the manufacturer; maximum power is available only within the limits and for the period stated in the documentation. Generator sizing should be based primarily on rated power. The maximum value must not be regarded as continuous capacity. A margin should also be allowed for load changes and starting currents.
Starting current is the peak demand at start-up from equipment fitted with a motor or compressor. For a few moments, it may exceed the power demand indicated during normal operation. If the generator lacks the required reserve, its voltage may drop or a protection device may activate. For a correct calculation, consult the appliance manufacturer's information and consider which items will start simultaneously.
The presence of an AVR must be checked on the individual model data sheet. This device automatically regulates the output voltage and limits variations within the system's specified operating conditions. It is not the same as inverter technology and does not automatically make every generator suitable for every electronic device. Before making a connection, check the instructions for both the generator and the appliance to be powered.
Maintenance includes periodic checks of the engine oil, filters, battery, fuel, fasteners and general condition. Intervals and procedures vary according to the engine and model, so the manual must be followed. After long periods of inactivity, check the starting system, fluid levels and condition of the fuel. Periodic tests of automatic systems must follow the system procedures and the manufacturer's instructions.
A generator with an internal-combustion engine must operate outdoors, in a ventilated space and protected in accordance with the manufacturer's instructions. Exhaust gases contain carbon monoxide and must not reach enclosed spaces, doors, windows or air intakes. The machine must be placed on a stable surface, away from flammable materials and protected from conditions that are not permitted. Clearances, earthing and protections must comply with the manual and applicable regulations.