Whole range of 5 Generators Einhell models, offered for sale from € 369.37 , in Prompt Delivery and Free shipping . Purchase directly from AgriEuro with no third parties nor unwanted surpreses: compared to the other online markets, who rely on third dealers (it means no assistance nor warranty), we offer Direct and Complete Assistance, which starts from pre-sales service up to after-sales assistance. The items are directly shipped from our AgriEuro distribution centre. Thus, we are the only online seller providing After-Sales Assistance for the Generators Einhell products and supplying Spare Parts (you access the exploded drawing once entered your Account).
Einhell power generators, also known as Einhell generating sets, provide an independent electricity supply for tools, appliances and equipment when mains power is unavailable. The brand was founded in 1964 in Landau an der Isar, Bavaria, when Josef Thannhuber took over his uncle Hans Einhell's business. The company began expanding across Europe in 1968 and gradually established a commercial presence in over 99 countries, extending its range for DIY, workshops, homes and gardens. It has operated in Italy since 1993 and has premises in Binago, in the province of Como. The models in the range meet different requirements, including powering tools on building sites or in workshops, supplying electricity in garages and isolated buildings, outdoor activities and temporary work where no electrical socket is available.
This page also includes the following types of Einhell generators, classified according to their power-delivery technology and intended application:
At AgriEuro, Einhell power generators can be selected according to their technical features, helping users find a model suited to the appliances requiring power and the expected frequency of operation. Before choosing, add together the power consumption of the intended appliances, take any starting peaks into account and compare the result with the stated continuous output.
Compact models are intended for domestic use, including camping, outdoor activities or the occasional supply of compatible small appliances. Units with higher output and larger fuel tanks meet semi-professional requirements, such as powering tools in workshops, maintenance work on isolated properties and temporary jobs. Compatibility must always be checked against the rating data of both the generator and the connected appliances.
The range includes generators with different designs, which should be compared according to output quality, required power and portability. Inverter technology is suitable for compatible electronic appliances; conventional petrol models offer output levels and fuel-tank capacities suited to equipment with higher power requirements. Selection should always begin with the appliances to be connected, their initial starting demand and the expected operating time.
Einhell inverter power generators electronically convert and regulate the electricity before it reaches the sockets. This design makes the output suitable for compatible appliances containing electronics, including laptops, battery chargers and devices used during outdoor activities. The range includes compact petrol units with air-cooled, four-stroke engines and 230 V sockets; certain models also feature USB ports. Continuous output, maximum output, number of sockets and running time vary between versions and must be compared with the actual load. Their compact dimensions make transport easier between garages, campsites, mobile workshops and buildings without mains power. Overload control and low-oil protection, where fitted, protect the main components of the machine. Before connecting appliances, the combined power consumption and initial peaks must remain within the values shown in the technical specifications.
Einhell petrol power generators use an internal combustion engine coupled to a synchronous generator and cover a range of outputs suitable for different jobs. Models with four-stroke engines can power compatible tools, lighting and equipment in workshops, garages, building sites or isolated buildings. AVR regulation, available on equipped units, controls the voltage as the load changes; it is not the same as the electronic conversion provided by inverter models. Fuel tanks of different capacities allow users to choose between portability and operating time. Larger configurations may include two 230 V sockets, additional outputs, a voltmeter, fuel gauge, wheels and handles. Certain versions also feature electric starting. Comparisons should consider continuous output, temporary maximum output, appliance starting currents and the stated running time at a specific load, without exceeding the limits of the machine.
AgriEuro supports product selection with detailed technical specifications and useful information for comparing output, fuel type and equipment. After purchase, dedicated services continue to support the product throughout its operating life.
Buy the Einhell power generator best suited to your requirements from AgriEuro now.
Choose the output by adding together the power consumption of all appliances that will operate simultaneously and accounting for starting current. Motors, compressors, pumps and certain tools require more power when starting than during normal operation. Compare the result with the generator's continuous output, not only with the maximum value available for short periods. A margin below the rated limit should be maintained, and the voltage, socket type and instructions in the appliance manuals must be checked. If starting-current figures are unavailable, request them from the appliance manufacturer or consult a qualified technician.
Continuous output is the power the generator can supply during normal operation under the conditions stated by the manufacturer. Maximum output is available only for a limited period and covers temporary demand within the specified limits. Generator sizing should therefore not be based solely on the maximum figure shown in the specifications. A load close to or above the continuous limit can activate overload protection, cause voltage drops or interrupt the supply. The permitted peak duration, simultaneous power consumption and starting currents of connected appliances must also be considered.
An Einhell inverter generator is suitable when compatible appliances containing electronic components require an electronically regulated output. Examples may include laptops, battery chargers, small devices and equipment approved by the manufacturer. The compact format also suits mobile applications, camping and activities in places without mains electricity. Inverter technology does not remove the need to check output: all loads must be added together, starting peaks included and socket limits observed. Consult both the generator manual and the manual of the appliance before making a connection.
AVR, or automatic voltage regulation, controls the output voltage when the connected load changes. It is fitted to several Einhell synchronous petrol generators and helps keep the supply within the parameters specified for the machine. It should not be confused with inverter technology: AVR regulates voltage but does not perform the same complete electronic conversion of the output. The presence of AVR does not mean that every appliance can be connected. Compatibility, output, frequency, required supply quality and manufacturer instructions must be checked before starting.
Running time depends on the fuel-tank capacity, applied load, model and operating conditions. Einhell specifications often state running time at a precise fraction of the load, such as two-thirds: this figure provides a reliable comparison only between machines measured under the same conditions. Connecting larger loads increases consumption and may shorten the operating time, as can frequent fluctuations in demand. Before planning a session, consult the stated figure for the selected model and refuel only when the engine is switched off and cool, in accordance with the manual. Never add fuel near flames, sparks or hot surfaces.
Yes, provided the tool's rated power and starting current remain within the generator limits. Drills, saws, compressors, pumps and other motor-driven equipment may draw more power when starting than during normal operation. Simply adding the rated wattages may therefore underestimate the actual requirement. Check the starting coefficient or figure in the tool manual, include any other connected loads and compare the total with the continuous and temporary performance of the generating set. If the figures are unclear, the assessment should be entrusted to a technician or the equipment manufacturer.
A petrol generator must operate outdoors, on a stable surface and in a well-ventilated position, observing the distances and conditions specified in the manual. Never run it inside a house, garage, cellar, enclosed shed or any other place where exhaust gases can accumulate: carbon monoxide is odourless and can be fatal. Keep the machine away from flammable materials, rain, standing water and walkways where cables or hot components could create a hazard. The exhaust must also face away from doors, windows and air vents. Connections to fixed installations require a qualified electrician.
Maintenance includes the checks specified in the manual for the individual model, with particular attention to engine oil, air filter, spark plug, fuel and fasteners. Intervals and procedures vary according to the engine and operating hours, so no single schedule applies to the entire range. Before every start, check for leaks, inspect cables, verify the oil level and ensure the ventilation openings are clean. Fuel should not remain in the circuit beyond the period stated by the manufacturer. Perform all work with the machine switched off, cool and disconnected from loads; technical repairs should be entrusted to the appropriate support service.
No. A direct connection using improvised sockets or cables is dangerous and may feed voltage back into the grid, exposing people and installations to serious risks. Supplying domestic circuits requires a suitable changeover system, coordinated protective devices and an installation designed in accordance with applicable regulations. The work must be assessed and completed by a qualified electrician, who will also check earthing, neutral configuration, available output and load compatibility. To power individual appliances, use only sockets, cables and extension leads permitted by the manual and with conductor sizes suitable for the current and connection length.
First select an output proportionate to the loads and disconnect appliances that are not required. An oversized generator or one operated outside its intended conditions may consume more fuel than necessary; an undersized model operates close to its limit and may activate its protective devices. Depending on their design, inverter generators can adapt engine speed to load demand, with favourable effects on consumption and noise at low loads. The machine must stand on a stable surface without its ventilation openings being covered. Homemade enclosures or barriers that obstruct cooling and exhaust flow must not be used.