Technical data
Configuration
Pump only
Water pump type
Diaphragm
Number of diaphragms
2
Flow rate
19 L/min
Max. operating pressure
30 bar
Motor type
Tractor-driven PTO
Absorbed power
1.6 HP
Type of attachment
Universal
Manufacturing country
Italy
Product Features
Model
MP 20
Type
Two membranes
Configuration
Pump only
Motor type
Tractor PTO
Operating mode
Tractor-driven PTO
Configuration
Pump only
Flow rate
19 L/min
Max. operating pressure
30 bar
Manufacturing country
Italy
Motor data
Motor type
Tractor-driven PTO
Type of attachment
Universal
Absorbed power
1.6 HP
Pump data
Pump brand
Comet
Number of diaphragms
2
Water pump type
Diaphragm
Manufacturing country
Italy
Free gifts/extra features
Instructions manual
Yes
Dimensions
Net weight
6.6 Kg
Packaging
Original packaging
Original packaging/s dimensions in cm (L x W x H)
25.30x24.50x31
Weight including packaging
10 Kg
Assembly time
Assembled

Add Accessories and get a discount
You're viewing:
Customers also viewed:
Description

Comet MP20 Tractor Mounted Pump

For spraying treatments in medium-sized crops. Application on trailed or wheeled sprayers, tractors, two-wheel tractors and sprayer pump units. The parts in contact with liquid are made of plasticized aluminium.

New 2-membrane configuration.

Hydraulic accumulator. Discharge connection with hook for direct application on the pump of the hose connector or of the control unit.

The PRESSURE REGULATION UNIT and the male or female PTO to operate it complete the equipment to use the machine.

After that, the product is complete and can be used by connecting it to your tractor. You can find and purchase these accessories in the tab "related products" at the top.

NOTE:

If products containing minerals such as kaolin, zeolite, basalt, etc. are used, washing should be carried out at the end of each treatment and at the end of each season to avoid long-term damage to the internal components of the pump. It is advisable to disassemble several parts of the pump, such as valves, heads and diaphragms, in order to clean out any agglomerated residues sedimented by the minerals.
These procedures will ensure a long life of the pump even if the above minerals are used.

Main Features

Performance

N. of membranes/pistons
2
Flow rate
19.5 l/min
Pressure
30.0 bar
Power
1.6 CV
RPM
550
Weight
6.6 Kg

It allows to operate:

  • 2 MITRA lances simultaneously

Feet for storage included

Connection for the control unit

You can combine the control group you prefer by purchasing it separately during the order completion phase or by browsing the related products.

Configurations Available

Two main examples on how to complete your pump with the accessories you find in the "RELATED PRODUCTS" tab:

Pump configuration for direct connection to the tractor PTO:

  • pressure regulation unit to mount directly on the pump
  • female power take-off to mount directly on the pump, equipped with supports with chains
  • * the pump is complete and ready to use

Pump configuration by connecting it via cardan shaft:

  • pressure regulation unit to mount directly on the pump
  • male power take-off to mount directly on the pump, to connect the tractor cardan shaft to the pump
  • * the pump is complete and ready to use

Recommendations for Use - Sprayer Pumps

To ensure the spray pump remains efficient and reliable over time, it is essential to clean the circuit thoroughly after each treatment and to carry out regular maintenance on the main components.

Residues from the products used can build up inside the pump, particularly on valves, their seats, diaphragms, seals and tubes, leading to the formation of deposits, blockages and limescale.

For this reason, after each use, it is recommended that the circuit be thoroughly flushed with clean water, allowing the water to circulate through the pump to remove as much residue from the solution used as possible.

It is also important to always follow the dilution ratios specified by the manufacturer of the product used, avoiding excessive concentrations or the introduction of substances into the circuit that have not been properly dissolved.

A properly prepared solution reduces the build-up of deposits and helps to preserve the pump’s internal components.

When using mineral-based products or substances prone to settling, it is advisable to have an agitator or mixing system inside the tank.

Continuous agitation keeps the product in suspension and reduces settling at the bottom.

EXTRAORDINARY MAINTENANCE

At the end of the season, it is advisable to carry out a more thorough inspection of the pump, removing the valves from their seats to eliminate any residues or limescale.

It is also advisable to remove the membrane heads, check the condition of the membranes and remove any deposits present inside.

It is important to check and replace the oil in accordance with the instructions, timings and specifications set out in the manufacturer’s user and maintenance manual.

Proper cleaning and regular maintenance help to maintain the pump’s performance and extend its service life.

Feedback & Reviews
5,00
5,00
5,00
5,00
5,00
5,00
5,00
All customers' pictures
All customers' video
Ordina per:
Ordina per:
Ordina per:
Filtra le recensioni che citano:
Questions & Answers