Whole range of 1 Sprayer Pumps Eurosystems models, offered for sale from € 2,499.54 , in Prompt Delivery and Free shipping . Purchase directly from AgriEuro with no third parties nor unwanted surpreses: compared to the other online markets, who rely on third dealers (it means no assistance nor warranty), we offer Direct and Complete Assistance, which starts from pre-sales service up to after-sales assistance. The items are directly shipped from our AgriEuro distribution centre. Thus, we are the only online seller providing After-Sales Assistance for the Sprayer Pumps Eurosystems products and supplying Spare Parts (you access the exploded drawing once entered your Account).
Eurosystems was founded in 1973 in Luzzara, in the province of Reggio Emilia, at the heart of an area closely connected to farming. The company has gradually expanded its range, adding cleaning, mowing, transport and crop treatment equipment to its cultivators, rotary tillers and scythe mowers. Design, testing and production in Italy enable direct control over materials and manufacturing processes.
Eurosystems sprayer pumps are designed for the controlled distribution of liquid solutions in vegetable gardens, gardens, orchards and small crops. The trolley and tank configuration facilitates movement between rows, flower beds and plants located far from the solution preparation point. This arrangement avoids carrying the liquid on the operator’s back and provides greater autonomy than compact portable sprayers.
At AgriEuro, Eurosystems sprayer pumps can be selected according to the most important technical features, helping to identify a configuration suited to the surface, treatment frequency and distance between the tank and crops. The assessment should consider both transport capacity and circuit performance during spraying.
This configuration is suitable for domestic and semi-professional activities, including the periodic care of vegetable gardens, gardens, small orchards and crop rows. The choice should be based on the actual surface to be treated, the frequency of work and the condition of the ground over which the trolley will travel.
Eurosystems trolley-mounted machines combine the tank, pump and distribution components within a mobile frame. This configuration meets the needs of operators who must reach several locations without carrying the liquid on their backs. The machine can be positioned near the work zone and moved at the end of each operation.
Eurosystems trolley-mounted sprayer pumps with tank are designed for treatments that require a mobile liquid supply and an operator-controlled lance. The trolley frame allows the machine to be transported along paths, between vegetable garden rows or close to hedges and trees without directly carrying the weight of the tank. The solution is suitable for distributing products authorised for the crop, foliar fertilisers and weed-control products, in compliance with labels and applicable requirements. The hose and lance allow the operator to work at a distance from the machine and direct the spray towards specific points. Before treatment, the fittings, hose, filter, nozzle and pressure should be checked. Afterwards, the circuit must be emptied and rinsed according to the manual, preventing residues and deposits from affecting subsequent spraying operations.
AgriEuro complements its selection of Eurosystems sprayer pumps with services dedicated to delivery, maintenance and post-purchase requirements. Support continues after the machine has been received, with access to spare parts and a specialised after-sales service.
Purchase the Eurosystems sprayer pump best suited to your spraying and weed-control work from AgriEuro.
A trolley-mounted sprayer pump with tank is used to distribute liquid solutions through a lance or a specific delivery device. It can be employed in vegetable gardens, gardens, orchards and small crops for treatments permitted for the product being applied. The trolley supports the weight of the solution and allows the machine to be moved between different work zones. Every product must be measured and applied according to its label, the manufacturer’s instructions and the requirements governing the treatment.
The trolley avoids carrying the weight of the tank on the operator’s back, an important difference when treatment requires a substantial quantity of liquid. The wheels facilitate movement over even surfaces and along accessible routes. A trolley-mounted machine may also provide a larger supply than compact portable models. Before making a choice, the width of passageways, slopes, uneven ground and the presence of steps should be considered, as these factors affect mobility.
Capacity should be selected according to the surface to be treated, required solution volume and distance from the refill point. A larger tank reduces the number of stops but increases the machine’s weight and overall size when full. For an accurate assessment, the average consumption for the treatment should be calculated and compared with the capacity stated in the technical data. It is also necessary to check that the trolley can pass through all intended access points.
Pressure and flow rate determine spraying performance. Pressure affects droplet formation and spraying range; flow rate indicates the quantity of liquid delivered per unit of time. Both values must be compatible with the nozzle, lance and type of treatment. Excessive pressure can produce droplets that are too fine and increase drift; insufficient pressure can cause an uneven spray. Adjustment must always comply with the manufacturer’s specifications.
Adjustment should begin with clean water and the machine stationary in stable conditions. After checking the filter, hose, fittings and nozzle, the pump is started according to the procedure in the manual. Pressure is set gradually and checked on the pressure gauge, where fitted. A brief spraying test is useful for observing the shape and consistency of the spray. Only after these checks should the required solution be prepared, following the stated doses, compatibility information and protective equipment requirements on the label.
A loss of pressure may be caused by a blocked filter, air entering the suction line, a crushed hose, loose fittings, leaks, a worn nozzle or incorrect adjustment. Before working on the pump, the entire liquid path should be checked, starting from the tank and suction filter. The hoses, valves, pressure gauge and lance should then be examined. If the issue remains after cleaning and tightening the connections, consult the manual or request a technical inspection.
Cleaning should be carried out immediately after every treatment, following the instructions for both the machine and the product used. After any remaining solution has been disposed of correctly, the tank and circuit are rinsed with clean water according to the specified procedure. The rinsing water is also passed through the hose, lance and nozzle. Filters and removable components should be checked separately. Residues and contaminated water must not be discharged into drains, waterways or unauthorised surfaces.
A blocked nozzle should be removed and cleaned with water, a soft brush or compressed air, where permitted by the manual. Needles, metal wires and sharp objects should not be inserted into the opening, as they may alter its diameter and change the flow rate. After refitting, a test should be carried out with clean water, checking the shape and consistency of the spray. If output remains uneven or the flow rate is abnormal, the nozzle should be replaced with a compatible component.
Before starting, check the condition of the tank, cleanliness of the filters, tightness of the fittings and condition of the hose and lance. The wheels and frame should be stable, with no loose components. If the machine has a pressure gauge, its display should be clearly readable and the needle should return correctly to zero. A clean-water test should also be performed to check for leaks. The intervals and procedures in the manual apply to the engine, pump and other mechanical components.
Before storage, the machine should be emptied, washed and dried carefully. The tank, circuit, filter, hose and lance should contain no solution residue. The pump should be stored in a dry, covered place protected from frost, as water remaining in the circuit may damage components at low temperatures. The hose should not be bent or crushed. Before the new season begins, a complete inspection and a clean-water test are recommended.