Hills with trees
Cutting weed
Spare Parts + After-Sales Assistance
5% off
from the 2nd item
The 30-day free return

Stanley sil air 244/24 - Electric Wheeled Air Compressor - 1.5 Hp - 24 L Oilless - Silenced

Add a question
ID: K502412

EAN: 8016738766875

MPN: B4CA304STF558

7,0/10
After-sales assistance & Spare parts
Stanley sil air 244/24 - Electric Wheeled Air Compressor - 1.5 Hp - 24 L Oilless - Silenced
Special offer
Free gifts from AgriEuro
2 compressor guns2 compressor guns
Spiral hose 5 metresSpiral hose 5 metres
Prompt Delivery
1 item in stock
Free Shipping
Estimated delivery: 24/09/2026 - 28/09/2026
Lowest price:
€ 344,57
-8 %
€ 317,00
Vat included
Technical data
Air compressor tank
24 L
Max. operating pressure
8 bar
Air intake flow
116 L/min
Cylinder head rpm
1440 RPM
Lubrication
Oil-less
Pump type
Single-stage
Silenced
Yes
Nominal power
1.5 HP
Operating mode
Single-phase 230 V
Pump unit mounting
Welded
Product Features
Model
Sil air 244/24
Air compressor type 2
Oilless
Air compressor type
Horizontal
Operating mode
Single-phase 230 V
Max. operating pressure
8 bar
Number of tanks
1
Air compressor tank
24 L
Pump unit mounting
Welded
Manufacturing country
China
Motor data
Motor type
Electric single-phase
Nominal power
1.5 HP
Silenced
Yes
Power supply
220 V electric
Noise level
84 dB(A)
Sound pressure perceived by the User
64 dB(A)
Manufacturing country
China
Pump data
Pump brand
Stanley
Model
sil air 244/24
Air intake flow
116 L/min
Pump type
Single-stage
Lubrication
Oil-less
No. of cylinders
1
Cooling manifold
No
Manufacturing country
China
Transmission data
Transmission type
Coaxial type direct
Cylinder head rpm
1440 RPM
Equipment
No. of outlet couplings
1
Rear wheels size
120 mm
Rubber-coated soft grip
Yes
Lifting handle
Yes
Free gifts/extra features
Wooden pallet (safe shipping)
Yes
Quick reduction coupling
Yes
Instructions manual
Yes
Dimensions and logistics
Net weight
26 Kg
Packaging
On pallet
Weight including packaging
26 Kg
Assembly time
5 minutes

Add Accessories and get a discount
You're viewing:
Customers also viewed:
Description

Stanley sil air 244/24 Electric Air Compressor - 24 L - 1.5 Hp - Oilless - Silenced

Stanley sil air 244/24 Air Compressor
Main features:
SIL = silenced model
244 = oilless cylinder head
24 = 24 L tank

The Stanley sil air 244/24 air compressor is regarded as the best choice among the hobbyists users, who are looking for a reliable, silent, lightweight and high-performing equipment.

Powered by a 1.5 Hp electric motor, this air compressor features a compressed air suction capacity of 130 L/min. It is capable of reaching a maximum pressure of 8 bar.

It comes with a large-sized compressed air storage tank of 24 L. It weighs 26 Kg and can be easily transported thanks to its wheels and to the upper handle.

This air compressor belongs to the Stanley silenced line.

Maintenance operations are also reduced, as no control or topping up of lubricating oil is required, as well as the transportability of these compressors, since there is no risk of oil leakage even when the air compressor is laid down on its side, for example to load it into the trunk of a car.

Technical features

Air intake flow: 130 L/min


Pumping unit type: coaxial - oil-free

Pressure: 8 bar

Electric motor power: 1.5 Hp

Tank: 24 L


Overall dimensions:
- Width: 600 mm
- Height: 600 mm
- Depth (or thickness): 330 mm

Weight: 26 kg

Controls

The Stanley sil air 244/24 air compressor features easy and user-friendly controls, which are divided into:

Power switch

Output air pressure gauge

Tank air pressure gauge

Air compressor female outlet fitting

Pressure adjusting knob

Other features

Schuko plug

Ergonomic handle for transportation

Large sturdy plastic wheels

Anti-vibration rubber pad

Condensate drain valve

Recommendations for use - Electric Air Compressors

Recommendations for use

To ensure maximum durability and efficiency of the machine, the following instructions must be strictly observed. Failure to do so constitutes improper use, with a serious risk of damage to the product (such damage is not covered by the warranty).

  • Tank maintenance and condensate drainage: Moisture contained in the intake air accumulates as condensate at the bottom of the tank, due to the thermal processes generated during compression. Drain the condensate after each use by operating the lower drain valve, turning it carefully to avoid sudden discharges of compressed air and liquid. Failure to carry out this maintenance task may lead to internal corrosion of the tank. Furthermore, condensate accumulation reduces the effective air volume, causing abnormal motor restart cycles and the transfer of impurities to connected tools, with the resulting risk of premature damage to the entire system.
  • Suitability of extension leads: Do not use unsuitable extension leads. Given the  high motor power, it is essential to ensure a constant power supply. Undersized cabling causes voltage drops that prevent the motor from reaching the correct speed, leading to abnormal overheating and permanent damage to electrical components. Use only cables with a minimum cross-section of 2.5 mm². This cross-section is necessary to handle the high current absorption, especially during start-up.

Unwind the extension lead completely before use. Never use the machine if the power cable is partially coiled or bunched up. Heat build-up due to induction can melt the cable and cause serious electrical damage to the motor or a fire hazard.

  • Operating position:  The air compressor must only be installed in environments free from humidity, preferably in dry locations that are fully protected from weather exposure and potential water splashes. Adequate ventilation must be ensured by maintaining a clearance of at least 50 cm between the machine and any wall or obstacle, in order to allow for proper air circulation and effective heat dissipation. The installation area must also guarantee a high level of air cleanliness and be free from dust, fumes, chemical vapours, or flammable gases. Failure to comply with these requirements exposes the product to the following risks:
  1. Critical overheating: insufficient ventilation or installation in confined spaces impairs the cooling of the motor and pump assembly, resulting in reduced service life.
  2. Safety risks: the presence of volatile or flammable substances may compromise the structural integrity of the machine or the safety of the operator.

 

  • Obstruction of cooling and ventilation systems:  During machine operation, the air compressor must not be covered with sheets, boxes or makeshift casings, as such barriers prevent the air flow required for cooling the internal components. Blocking the ventilation slots causes a rapid rise in operating temperature, with the consequent risk of irreversible damage to the motor and the seals of the pumping unit. If protective covers are used during periods of inactivity, these must be completely removed before any start-up attempt to ensure the full efficiency of the heat dissipation system, thus preventing critical overheating.
  • Power supply and connections suitability: The air compressor must be connected exclusively to an electrical socket rated for the motor’s nominal power. Avoid using unsuitable sockets or connections located too far from the main electrical system. Failure to comply with these requirements exposes the machine to insufficient voltage conditions, seriously compromising the start-up phase, causing start-up difficulties, abnormal stresses and the sudden tripping of protective devices (circuit breakers or residual-current devices).
  • Shutdown procedure and static pressure management: It is recommended not to leave the tank pressurised during periods of inactivity. After switching off (OFF position), the residual pressure must be released and the drain valve opened, leaving the tank empty in order to promote the evaporation of internal moisture. Maintaining constant pressure, in fact, promotes condensation build-up and accelerates the deterioration of pneumatic components, such as diaphragms and valves, drastically reducing the overall reliability of the system and its operational life.
  • Checking the oil level: Before each use, check the oil level in the pumping unit. The level must fall within the range indicated by the oil level indicator or the dipstick, if fitted. Do not operate the air compressor if the oil level is too low, too high or if the oil is contaminated. An insufficient oil level can cause overheating, accelerated wear, seizure of the pumping unit and damage not covered by the warranty. An excessive oil level can cause leaks, oil leakage and oil carry-over into the compressed air circuit.

Operating position: Use the air compressor exclusively in a vertical position, on a flat and stable surface. Use on sloping surfaces may compromise the correct lubrication of the pumping unit.

Free items & Standard equipment

COMPLIMENTARY: GeoTech accessories kit for air compressors - 3 tools

This extensive air compressor accessories kit includes:

- Tyre inflating gun with
integrated pressure gauge

- Air blowing gun

- Coiled air hose

Standard equipment

The air compressor is shipped in its original packaging.

Instructions manual included.

Questions & Answers