Hills with trees
Cutting weed
Spare Parts + After-Sales Assistance
5% off
from the 2nd item
The 30-day free return

Stanley DST 100/8/6 -1HP Portable Compact Electric Air Compressor - 6 L

Add a question
ID: K601564

EAN: 8016738768763

MPN: B2BE104STN703

7,0/10
After-sales assistance & Spare parts
Stanley DST 100/8/6 -1HP Portable Compact Electric Air Compressor - 6 L
+600 sold
Free gifts from AgriEuro
2 compressor guns2 compressor guns
Spiral hose 5 metresSpiral hose 5 metres
Prompt Delivery
33 items in stock
Free Shipping
Estimated delivery: 13/10/2026 - 15/10/2026
€ 199,01
Vat included
Technical data
Air compressor tank
6 L
Max. operating pressure
8 bar
Air intake flow
105 L/min
Cylinder head rpm
1450 RPM
Lubrication
Oil-less
Pump type
Single-stage
Motor type
Induction
Nominal power
1 HP
Operating mode
Single-phase 230 V
Product Features
Model
DST 100/8/6
Air compressor type 2
Oilless
Air compressor type
Portable
Handheld
yes
Operating mode
Single-phase 230 V
Max. operating pressure
8 bar
Number of tanks
1
Tank capacity
6 L
Air compressor tank
6 L
Noise level
59 dBA
Manufacturing country
China
Motor data
Motor type
Induction
Nominal power
1 HP
Power supply
220 V electric
Pump data
Pump brand
stanley
Model
DST 100/8/6
Air intake flow
105 L/min
Pump type
Single-stage
Lubrication
Oil-less
No. of cylinders
1
Cooling manifold
No
Transmission data
Transmission type
Coaxial type direct
Cylinder head rpm
1450 RPM
Equipment
Anti-vibrating system
Yes
No. of outlet couplings
1
Lifting handle
Yes
Dimensions and logistics
Product dimensions in cm (L x W x H)
35x33x32 cm
Net weight
15.5 Kg
Packaging
Double packaging
Original packaging/s dimensions in cm (L x W x H)
36x36x37 cm
Weight including packaging
17 Kg
Assembly time
5 minutes

Add Accessories and get a discount
You're viewing:
Customers also viewed:
Description

STANLEY DST 100/8/6 1 Hp Electric Air Compressor - 6 L Oilless Silenced

The STANLEY DST 150/8/24 Silenced Wheeled Air Compressor is an innovative product. It represents a great choice for all hobbyists looking for a reliable, silent, lightweight and high-performing equipment.

Maintenance operations are also reduced, as no control or topping up of lubricating oil is required, as well as the transportability of these air compressor, since there is no risk of oil leakage even when the air compressor is laid down on its side, for example to load it into the trunk of a car.

Its discreet capacity (6 L) allows it to be easily transported and to be stored even in the smallest places.

Perfect for home use, it weights only 15.5 Kg, thus making it easy to transport.

This air compressor is equipped with an innovative silencer that drastically reduces noise emissions to 59 dBA.

Powered by a 1 Hp electric motor, it features a compressed air suction capacity of 105 L/min. It is capable of reaching a maximum pressure of 8 bar.

It comes with a large compressed air storage tank of 6 L. It weighs 15.5 Kg and can be easily transported thanks to the practical upper handle.

This air compressor belongs to the Stanley silenced line.

Technical features

Air intake flow: 105 L/min

Pumping unit type: coaxial

Pressure: 8 bar

Electric motor power: 1 Hp

Tank: 6 L

The noise emissions can be measured both in dB and Lwa. In detail:

Noise emissions 59 dBA

Same value expressed in LwA: 79 dB

Overall dimensions:
- Width: 35 mm
- Height: 33 mm
- Depth (or thickness): 32 mm

Weight: 15.5 Kg

Controls

The STANLEY DST 100/8/6 air compressor features easy and user-friendly controls, which are divided into:

Output air pressure gauge

Power switch

Female outlet fitting

Pressure adjusting knob

Other features

Schuko plug

Ergonomic lifting handle

Anti-vibration rubber pads

Condensate drain valve

Recommendations for Use - Electric Air Compressors

Recommendations for use

To ensure maximum durability and efficiency of the machine, the following instructions must be strictly observed. Failure to do so constitutes improper use, with a serious risk of damage to the product (such damage is not covered by the warranty).

  • Tank maintenance and condensate drainage: Moisture contained in the intake air accumulates as condensate at the bottom of the tank, due to the thermal processes generated during compression. Drain the condensate after each use by operating the lower drain valve, turning it carefully to avoid sudden discharges of compressed air and liquid. Failure to carry out this maintenance task may lead to internal corrosion of the tank. Furthermore, condensate accumulation reduces the effective air volume, causing abnormal motor restart cycles and the transfer of impurities to connected tools, with the resulting risk of premature damage to the entire system.
  • Suitability of extension leads: Do not use unsuitable extension leads. Given the  high motor power, it is essential to ensure a constant power supply. Undersized cabling causes voltage drops that prevent the motor from reaching the correct speed, leading to abnormal overheating and permanent damage to electrical components. Use only cables with a minimum cross-section of 2.5 mm². This cross-section is necessary to handle the high current absorption, especially during start-up.

Unwind the extension lead completely before use. Never use the machine if the power cable is partially coiled or bunched up. Heat build-up due to induction can melt the cable and cause serious electrical damage to the motor or a fire hazard.

  • Operating position:  The air compressor must only be installed in environments free from humidity, preferably in dry locations that are fully protected from weather exposure and potential water splashes. Adequate ventilation must be ensured by maintaining a clearance of at least 50 cm between the machine and any wall or obstacle, in order to allow for proper air circulation and effective heat dissipation. The installation area must also guarantee a high level of air cleanliness and be free from dust, fumes, chemical vapours, or flammable gases. Failure to comply with these requirements exposes the product to the following risks:
  1. Critical overheating: insufficient ventilation or installation in confined spaces impairs the cooling of the motor and pump assembly, resulting in reduced service life.
  2. Safety risks: the presence of volatile or flammable substances may compromise the structural integrity of the machine or the safety of the operator.

 

  • Obstruction of cooling and ventilation systems:  During machine operation, the air compressor must not be covered with sheets, boxes or makeshift casings, as such barriers prevent the air flow required for cooling the internal components. Blocking the ventilation slots causes a rapid rise in operating temperature, with the consequent risk of irreversible damage to the motor and the seals of the pumping unit. If protective covers are used during periods of inactivity, these must be completely removed before any start-up attempt to ensure the full efficiency of the heat dissipation system, thus preventing critical overheating.
  • Power supply and connections suitability: The air compressor must be connected exclusively to an electrical socket rated for the motor’s nominal power. Avoid using unsuitable sockets or connections located too far from the main electrical system. Failure to comply with these requirements exposes the machine to insufficient voltage conditions, seriously compromising the start-up phase, causing start-up difficulties, abnormal stresses and the sudden tripping of protective devices (circuit breakers or residual-current devices).
  • Shutdown procedure and static pressure management: It is recommended not to leave the tank pressurised during periods of inactivity. After switching off (OFF position), the residual pressure must be released and the drain valve opened, leaving the tank empty in order to promote the evaporation of internal moisture. Maintaining constant pressure, in fact, promotes condensation build-up and accelerates the deterioration of pneumatic components, such as diaphragms and valves, drastically reducing the overall reliability of the system and its operational life.
  • Checking the oil level: Before each use, check the oil level in the pumping unit. The level must fall within the range indicated by the oil level indicator or the dipstick, if fitted. Do not operate the air compressor if the oil level is too low, too high or if the oil is contaminated. An insufficient oil level can cause overheating, accelerated wear, seizure of the pumping unit and damage not covered by the warranty. An excessive oil level can cause leaks, oil leakage and oil carry-over into the compressed air circuit.

Operating position: Use the air compressor exclusively in a vertical position, on a flat and stable surface. Use on sloping surfaces may compromise the correct lubrication of the pumping unit.

Free items & Standard equipment

COMPLIMENTARY: GeoTech accessories kit for air compressors - 3 tools

This extensive air compressor accessories kit includes:

- Tyre inflating gun with
integrated pressure gauge

- Air blowing gun

- Coiled air hose

Standard equipment

The air compressor is shipped in its original packaging.

Instructions manual included.

Feedback & Reviews
5,00
5,00
5,00
5,00
5,00
5,00
5,00
All customers' pictures
All customers' video
Ordina per:
Ordina per:
Ordina per:
Filtra le recensioni che citano:
Questions & Answers