Hills with trees
Cutting weed
Spare Parts + After-Sales Assistance
5% off
from the 2nd item
The 30-day free return

GeoTech S-AC-9-8-07 - Portable Compact Silenced Electric Air Compressor - 0.7 Hp Motor - 8 bar

Questions & Answers (23)
ID: K502307

EAN: 8053435093026

MPN: S-AC-9-8-07

8,9/10
After-sales assistance & Spare parts
GeoTech S-AC-9-8-07 - Portable Compact Silenced Electric Air Compressor - 0.7 Hp Motor - 8 bar
+1000 sold
Free gifts from AgriEuro
Universal cover for storageUniversal cover for storage
Prompt Delivery
105 items in stock
Free Shipping
Estimated delivery: 03/12/2026 - 07/12/2026
Suggested price:
€ 195,34
€ 146,51
Vat included
Technical data
Air compressor tank
8 L
Max. operating pressure
8 bar
Air intake flow
100 L/min
Cylinder head rpm
1440 RPM
Lubrication
Oil-less
Pump type
Single-stage
Silenced
Yes
Nominal power
0.7 HP
Operating mode
Single-phase 230 V
Nominal power (W)
550 W
Pump unit mounting
Welded
Product Features
Model
S-AC-9-8-07
Air compressor type 2
Oilless
Air compressor type
Portable
Handheld
yes
Operating mode
Single-phase 230 V
Max. operating pressure
8 bar
Number of tanks
1
Tank capacity
8 L
Air compressor tank
8 L
Pump unit mounting
Welded
Manufacturing country
China
Motor data
Motor type
Electric single-phase
Nominal power
0.7 HP
Nominal power (W)
550 W
Silenced
Yes
Power supply
220 V electric
Noise level
79 dB(A)
Sound pressure perceived by the User
60 dB(A)
Manufacturing country
China
Pump data
Pump brand
GeoTech
Model
S-AC-9-8-07
Air intake flow
100 L/min
Pump type
Single-stage
Lubrication
Oil-less
No. of cylinders
1
Cooling manifold
No
Manufacturing country
China
Transmission data
Transmission type
Coaxial type direct
Cylinder head rpm
1440 RPM
Equipment
Anti-vibrating system
Yes
No. of outlet couplings
1
Rubber-coated soft grip
Yes
Lifting handle
Yes
Free gifts/extra features
Instructions manual
Yes
Dimensions
Product dimensions in cm (L x W x H)
45x17x56cm
Net weight
13 Kg
Packaging
Original packaging
Original packaging/s dimensions in cm (L x W x H)
51x22,5x52cm
Weight including packaging
16 Kg
Assembly time
5 minutes

Add Accessories and get a discount
You're viewing:
Customers also viewed:
Description

GeoTech S-AC-9-8-07 Electric Air Compressor

The Geotech S-AC-9-8-07 compressor is an ideal choice for doing it yourself enthusiast who want a practical tool designed to perform small jobs around the home with ease and peace of mind.

This model benefits from almost non-existent maintenance due to the absence of oil, eliminating the need for frequent checks or additions.

The design of the compressor contributes to ease of transport, its Oillessness eliminates the worry of potential leaks, allowing it to be stowed in any position, even sideways, as is often the case in the boot of the car.

With an 8 litre tank, the device maintains superior portability, adapting to tight and demanding spaces.

Lightweight at just 14.5kg, it is extremely manageable for anyone, making it perfectly suitable for home use.

The presence of a silencer drastically reduces the noise emitted by the unit to just 59dBA, allowing you to work without disturbing the quiet life.

Equipped with a 0.7 HP electric engine, this compressor has a suction performance of 100 Litres per minute and can exert a maximum pressure of 8 bar.

The Geotech S-AC-9-8-07 is part of the quiet, oil-free compressor range from Geotech, a brand synonymous with excellence and continuos technological innovation.

Technical features

Pumping unit type: coaxial

Air intake flow: 100 L/min

Pressure: 8 bar

Electric motor power: 0.7 Hp

Tank: 8 lt

The sound level can be measured in both dBA and Lwa. In detail:

Sound emission 59dBA

Sound emission in LwA 79dB


Dimensions:
- Width: 45 cm
- Height: 56cm
- Depth (or thickness): 17 cm

Weight: 14.5 kg

Controls

The S-AC-9-8-07 GeoTech air compressor features easy and user-friendly controls, which are divided into:

Output air pressure gauge

Power switch

Pressure adjusting knob

Air compressor female outlet fitting

Other features

Intake air production: 100Lt/min

Head type: single-cylinder with cast iron cylinder

Suction type: single-stage

Lubrication: Oillies

Speed: 1440 rpm

Schuko plug

Ergonomic lifting handle

Anti-vibration pads

Condensate drain valve

Recommendations for Use - Electric Air Compressors

Recommendations for use

To ensure maximum durability and efficiency of the machine, the following instructions must be strictly observed. Failure to do so constitutes improper use, with a serious risk of damage to the product (such damage is not covered by the warranty).

  • Tank maintenance and condensate drainage: Moisture contained in the intake air accumulates as condensate at the bottom of the tank, due to the thermal processes generated during compression. Drain the condensate after each use by operating the lower drain valve, turning it carefully to avoid sudden discharges of compressed air and liquid. Failure to carry out this maintenance task may lead to internal corrosion of the tank. Furthermore, condensate accumulation reduces the effective air volume, causing abnormal motor restart cycles and the transfer of impurities to connected tools, with the resulting risk of premature damage to the entire system.
  • Suitability of extension leads: Do not use unsuitable extension leads. Given the  high motor power, it is essential to ensure a constant power supply. Undersized cabling causes voltage drops that prevent the motor from reaching the correct speed, leading to abnormal overheating and permanent damage to electrical components. Use only cables with a minimum cross-section of 2.5 mm². This cross-section is necessary to handle the high current absorption, especially during start-up.

Unwind the extension lead completely before use. Never use the machine if the power cable is partially coiled or bunched up. Heat build-up due to induction can melt the cable and cause serious electrical damage to the motor or a fire hazard.

  • Operating position:  The air compressor must only be installed in environments free from humidity, preferably in dry locations that are fully protected from weather exposure and potential water splashes. Adequate ventilation must be ensured by maintaining a clearance of at least 50 cm between the machine and any wall or obstacle, in order to allow for proper air circulation and effective heat dissipation. The installation area must also guarantee a high level of air cleanliness and be free from dust, fumes, chemical vapours, or flammable gases. Failure to comply with these requirements exposes the product to the following risks:
  1. Critical overheating: insufficient ventilation or installation in confined spaces impairs the cooling of the motor and pump assembly, resulting in reduced service life.
  2. Safety risks: the presence of volatile or flammable substances may compromise the structural integrity of the machine or the safety of the operator.

 

  • Obstruction of cooling and ventilation systems:  During machine operation, the air compressor must not be covered with sheets, boxes or makeshift casings, as such barriers prevent the air flow required for cooling the internal components. Blocking the ventilation slots causes a rapid rise in operating temperature, with the consequent risk of irreversible damage to the motor and the seals of the pumping unit. If protective covers are used during periods of inactivity, these must be completely removed before any start-up attempt to ensure the full efficiency of the heat dissipation system, thus preventing critical overheating.
  • Power supply and connections suitability: The air compressor must be connected exclusively to an electrical socket rated for the motor’s nominal power. Avoid using unsuitable sockets or connections located too far from the main electrical system. Failure to comply with these requirements exposes the machine to insufficient voltage conditions, seriously compromising the start-up phase, causing start-up difficulties, abnormal stresses and the sudden tripping of protective devices (circuit breakers or residual-current devices).
  • Shutdown procedure and static pressure management: It is recommended not to leave the tank pressurised during periods of inactivity. After switching off (OFF position), the residual pressure must be released and the drain valve opened, leaving the tank empty in order to promote the evaporation of internal moisture. Maintaining constant pressure, in fact, promotes condensation build-up and accelerates the deterioration of pneumatic components, such as diaphragms and valves, drastically reducing the overall reliability of the system and its operational life.
  • Checking the oil level: Before each use, check the oil level in the pumping unit. The level must fall within the range indicated by the oil level indicator or the dipstick, if fitted. Do not operate the air compressor if the oil level is too low, too high or if the oil is contaminated. An insufficient oil level can cause overheating, accelerated wear, seizure of the pumping unit and damage not covered by the warranty. An excessive oil level can cause leaks, oil leakage and oil carry-over into the compressed air circuit.

Operating position: Use the air compressor exclusively in a vertical position, on a flat and stable surface. Use on sloping surfaces may compromise the correct lubrication of the pumping unit.

Free items & Standard equipment

COMPLIMENTARY: professional protection and storage cover cloth

Essential for protecting your machine when stored.

This cloth is fast and easy to apply; within seconds your machine is protected from dust and humidity.

Easy to fold and store inside its own box packaging with minimal space required!

Standard equipment

The air compressor is shipped in its original packaging.

Instructions manual included.

Feedback & Reviews
5,00
5,00
5,00
5,00
5,00
5,00
5,00
All customers' pictures
All customers' video
Ordina per:
Ordina per:
Ordina per:
Filtra le recensioni che citano:
Questions & Answers